Basic Information |
Part Number |
02355NEE
|
Model |
S5755-H48N4Y-A
|
Description |
S5755-H48N4Y-A (48*10/100/1000/2.5GBASE-T ports, 4*25GE SFP28 ports, built-in AC power, front access)
|
Technical Specifications |
Height [mm] |
43.6 mm
|
Depth [mm] |
220.0 mm
|
Wide [mm] |
442.0 mm
|
Chassis height [U] |
1
|
Weight with packaging [kg(lb)] |
4.71 (10.38)
|
Weight without packaging [kg(lb)] |
4.09 (9.02)
|
Maximum power consumption [W] |
100% traffic under the ATIS standard:
105 W
|
Typical power consumption [W] |
30% traffic under the ATIS standard:
101 W
|
Typical heat dissipation [BTU/hour] |
30% traffic under the ATIS standard:
313.91
|
Maximum heat dissipation [BTU/hour] |
100% traffic under the ATIS standard:
358.27
|
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Power supply mode |
AC built-in
|
Input voltage range [V] |
AC input: 90 V AC to 264 V AC, 47 Hz to 63 Hz
|
Rated input voltage [V] |
AC input: 100–240 V AC; 50/60 Hz
|
Maximum input current [A] |
3 A
|
Number of card slots |
0
|
Number of power slots |
0
|
Memory |
4 GB
|
Flash memory |
Physical space: 2 GB
|
Redundant power supply |
Not supported
|
Types of fans |
Built-in
|
Noise at normal temperature (acoustic pressure) [dB(A)] |
35.2
|
Noise at normal temperature (acoustic power) [dB(A)] |
47.2
|
Airflow direction |
Air intake from left and air exhaust from right
|
Short-term operating temperature [°C(°F)] |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Restriction on the operating temperature variation rate [°C(°F)] |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
- The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.
- The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
- The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.
|
Long-term operating temperature [°C(°F)] |
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)
|
Storage temperature [°C(°F)] |
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing)
|
Storage altitude [m(ft.)] |
0-5000 m (0-16404 ft.)
|
Long-term operating altitude [m(ft.)] |
0–5000 m (0–16404 ft.)
|
MTBF [year] |
45.5
|
MTTR [hour] |
2.64
|
Availability |
> 0.99999
|
Maximum number of physical ports on the entire device |
52
|
Maximum number of 100GE ports |
0
|
Maximum number of 40GE ports |
0
|
Maximum number of 25GE ports |
4
|
Maximum number of 10GE ports |
4
|
Maximum number of GE ports |
52
|
Maximum number of FE ports |
48
|
25G optical interface |
4
|
USB |
Not supported
|
Console port |
USB
|
Eth Management port |
RJ45
|
Power supply surge protection |
Differential mode: ±6 kV; common mode: ±6 kV
|
RPS input |
Not supported
|
PoE |
Not supported
|