Basic Information |
|
Part Number |
02354VCD
|
Model |
S5731-S8UM16UN2Q
|
Description |
S5731-S8UM16UN2Q (8*100M/1/2.5/5/10G,16*100M/1/2.5G ports, 2*40GE QSFP ports or 12*100M/1/2.5/5/10G,12*100M/1/2.5G ports, 4*10GE SFP+ ports, PoE++, without power module)
|
Technical Specifications |
Height [mm] |
43.6 mm
|
Depth [mm] |
420.0 mm
|
Wide [mm] |
442.0 mm
|
Chassis height [U] |
1
|
Weight without packaging |
6.83 kg (15.06 lb)
|
Weight with packaging |
9.81 kg (21.63 lb)
|
Typical power consumption [W] |
126
|
Maximum power consumption [W] |
- Without PoE: 171 W
- Full PoE load: 2571 W (PoE: 2268 W)
|
Heat dissipation mode |
Air cooling for heat dissipation, intelligent fan speed adjustment
|
Typical heat dissipation [BTU/h] |
429.93
|
Maximum heat dissipation [BTU/h] |
- Without PoE: 583.48
- Full PoE load: 8772.60
|
Power supply mode |
Pluggable power supply
|
Input voltage range [V] |
- AC input: 90 V AC to 290 V AC; 45 Hz to 66 Hz
- High-voltage DC input: 190 V DC to 290 V DC
- DC input: -38.4 V DC to -72 V DC
|
Rated input voltage [V] |
- AC input: 100 V AC to 130 V AC, 200 V AC to 240 V AC; 50/60 Hz
- High-voltage DC input: 240 V DC
- DC input: –48 V DC to –60 V DC
|
Maximum input current [A] |
The current specifications are related to the pluggable power module. For details, see Pluggable Power Modules.
|
Number of card slots |
0
|
Number of power slots |
3
|
Memory |
2 GB
|
Flash memory |
1 GB in total. To view the available flash memory size, run the display version command.
|
Redundant power supply |
1+1+1
Pluggable AC and DC power modules can be used together in the same switch.
|
Types of fans |
Built-in
|
Noise at normal temperature (acoustic power) |
Three 600 W AC PoE power modules with 30% load: 50.50 dBA
Three 1000 W AC PoE power modules with 30% load: 52.50 dBA
Three 1000 W DC PoE power modules with 30% load: 52.50 dBA
|
Noise at normal temperature (acoustic pressure) |
Three 600 W AC PoE power modules with 30% load: 36.82 dBA
Three 1000 W AC PoE power modules with 30% load: 38.82 dBA
Three 1000 W DC PoE power modules with 30% load: 38.82 dBA
|
Airflow direction |
Air intake from the front and left and air exhaust from the rear
|
Short-term operating temperature |
-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
|
Restriction on the operating temperature variation rate |
When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
The device can work for a short period of time when the operating temperature is beyond the normal range, but the following conditions must be met:
- The operating temperature can exceed 45°C (113°F) for a maximum of 96 consecutive hours in a year.
- The total time when the operating temperature exceeds 45°C (113°F) in a year is less than or equal to 360 hours.
- The number of times the operating temperature exceeds 45°C (113°F) is less than or equal to 15 in one year.
If any of the preceding conditions is not met, the device may be damaged or an unknown error may occur.
Devices cannot start when the temperature is lower than 0°C (32°F). The maximum transmission distance of an optical module used for short-term operation cannot exceed 10 km.
|
Long-term operating temperature |
–5°C to +45°C (23°F to 113°F) at an altitude of 0 to 1800 m (0 to 5905.44 ft.)
|
Storage temperature |
–40°C to +70°C (–40°F to +158°F)
|
Long-term operating relative humidity [RH] |
5% RH to 95% RH (non-condensing)
|
Long-term operating altitude |
0–5000 m (0–16404 ft.)
|
Storage altitude |
0-5000 m (0-16404 ft.)
|
MTBF [year] |
54.08
|
MTTR [h] |
2.22
|
Availability |
>0.99999
|
Maximum number of physical ports on the entire device |
28
|
Maximum number of 100GE ports |
0
|
Maximum number of 40GE ports |
2
|
Maximum number of 25GE ports |
0
|
Maximum number of 10GE ports |
16
|
Maximum number of GE ports |
24
|
Maximum number of FE ports |
24
|
USB |
Supported
|
Console port |
RJ45
|
Eth Management port |
RJ45
|
Service port surge protection |
Common mode: ±7 kV
|
Power supply surge protection |
- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode
- Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
|
RPS input |
Not supported
|
PoE |
Supported
|