Basic Information |
|
Part Number |
02354ARU-001
|
Model |
CR8PM1CBASC5
|
Description |
NetEngine 8000 M1C Basic Configuration (Includes M1C Chassis, Fixed Interface(16*10GE + 12*GE),2*AC Power,without Software and Document)
|
First supported version |
V800R021C10SPC600
|
Technical Specifications |
Height [mm] |
44.5 mm
|
Depth [mm] |
220 mm
|
Wide [mm] |
442 mm
|
Chassis height [U] |
1 U
|
Weight without packaging |
3.9 kg (8.60 lb)
|
Weight with packaging |
6.1 kg (13.45 lb)
|
Typical power consumption (with configuration) [W] |
89.21 W
|
Maximum power consumption (with configuration) [W] |
111.60 W
|
Maximum heat dissipation (with configuration) [BTU/h] |
362.08 BTU/hour
|
Typical heat dissipation (with configuration) [BTU/h] |
289.43 BTU/hour
|
Heat dissipation mode |
Air cooling
|
Power supply mode |
AC
|
Input voltage range [V] |
100 V to 240 V
|
Rated input voltage [V] |
200 V–240 V/100 V–127 V dual-live wire, supporting 240 V HVDC
|
Maximum input current [A] |
4 A
|
CPU |
8-core 1.5 GHz
|
SDRAM |
4 GB
|
Storage |
8 GB
|
Flash memory |
64 MB
|
Redundant fans |
If a single fan fails, the system can still work for a short period of time at an ambient temperature of 50°C (122°F).
|
Redundant power supply |
1+1
|
Noise at normal temperature (acoustic power) |
55 dB(A)
|
Airflow direction |
From left to right
|
Maximum input cable size |
Standard C13 cable
|
Front-end circuit breaker/fuse |
≥2A
|
Long-term operating temperature |
–40°C to +65°C (–40°F to +149°F)
|
Storage temperature |
–40°C to +70°C (–40°F to +158 °F)
|
Restriction on the operating temperature variation rate |
≤ 30°C/hour (54°F/hour)
|
Long-term operating relative humidity [RH] |
5% to 95% RH, non-condensing
|
Storage relative humidity [RH] |
5% to 100% RH, non-condensing
|
Storage altitude |
< 5000 m (16404 ft.)
|
Long-term operating altitude |
≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1°C [1.8°F] for every 220 m [721.78 ft.].)
|
MTBF [year] |
45.43
|
MTTR [h] |
2
|
Availability |
0.99999
|
Maximum number of 10GE ports |
16
|
Maximum number of FE ports |
28
|
Maximum number of physical ports on the entire device |
28
|
Maximum number of GE ports |
28
|
Maximum number of electrical ports |
4
|