Basic Information |
|
Part Number |
02354GCW-002
|
Model |
CE6863E-48S6CQ
|
Description |
CE6863E-48S6CQ switch (48*25GE SFP28, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side intake)
|
Technical Specifications |
Other part numbers |
02354GCT-002 (CE6863E-48S6CQ switch (48*25GE SFP28, 6*100GE QSFP28, without fan and power modules))
02354GCX-002 (CE6863E-48S6CQ switch (48*25GE SFP28, 6*100GE QSFP28, 2*AC power modules, 4*fan modules, port-side exhaust))
|
Installation Type |
Cabinet installation
|
Depth [mm] |
420.0 mm
|
Wide [mm] |
442.0 mm
|
Height [mm] |
43.6 mm
|
Weight without packaging |
5.7 kg (12.57 lb) (excluding optical modules, power modules, and fan modules)
|
Weight with packaging |
8.95 kg (19.73 lb)
|
Typical power consumption [W] |
226 W (100% throughput, SFP28 high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
261 W (100% throughput, short-distance optical modules on all ports, dual power modules)
|
Static power consumption [W] |
167 W
|
Maximum power consumption [W] |
384 W
|
Static heat dissipation [BTU/h] |
570 BTU/hour
|
Heat dissipation mode |
Air cooling
|
Typical heat dissipation [BTU/h] |
771 BTU/hr (100% throughput, SFP28 high-speed cables on 48 ports and QSFP28 high-speed cables on 6 ports, dual power modules)
891 BTU/hr (100% throughput, short-distance optical modules on all ports, dual power modules)
|
Maximum heat dissipation [BTU/h] |
1310 BTU/hour
|
Power supply mode |
AC,DC,HVDC
|
Rated input voltage [V] |
Rated AC input voltage range: 100 V AC to 240 V AC; 50/60 Hz
Rated –48 V DC input voltage range: –48 V DC to –60 V DC
Rated input voltage range for 600 W AC & 240 V DC: 240 V DC
Rated input voltage range for 1200 W HVDC: 240 V DC to 380 V DC
|
Input voltage range [V] |
Maximum AC input voltage range: 90 V AC to 290 V AC; 45 Hz to 65 Hz
Maximum –48 V DC input voltage range: –38.4 V DC to –72 V DC
Maximum input voltage range for 600 W AC & 240 V DC: 190 V DC to 290 V DC
Maximum input voltage range for 1200 W HVDC: 190 V DC to 400 V DC
|
Maximum input current [A] |
600 W AC&240 V DC power module (PAC600S12 series):
· 8 A (100 V AC to 240 V DC)
· 4 A (240 V DC)
1000 W DC power module (PDC1000S12 series): 30 A (–48 V DC to –60 V DC)
1200 W high-voltage DC power module (PHD1K2S12 series): 8 A
|
Rated output power [W] |
600 W (AC&240 V HVDC)
1000 W (–48 V DC)
1200 W (380 V HVDC)
|
Memory |
DRAM: 4 GB
|
NOR Flash |
64 MB
|
NAND Flash |
4 GB
|
USB |
Supported
|
Console port |
RJ45
|
Downlink Service interface |
48*25GE SFP28 (Note: 1. 25GE ports can be configured to work at 10 Gbit/s or 1 Gbit/s. Every four downlink 25GE ports form a group, and can be configured to work at 10 Gbit/s or 1 Gbit/s through the command. 2. 10GE LRM/80KM linear optical modules are not supported. 3. 1 m 25GE copper cables and 1 m/3 m/5 m 10GE copper cables are supported, and auto-negotiation of copper cables is not supported. 4. 25GE copper cables can be used only on stack ports and M-LAG peer-link ports.)
|
Uplink Service interface |
6*100GE QSFP28
Note:
1. Each 100GE QSFP28 port can be configured to work at 40 Gbit/s.
2. A 100GE QSFP28 port cannot be split into 4 x 25GE or 4 x 10GE ports.
3. 100GE and 40GE 1/3/5 m copper cables are supported, but auto-negotiation of copper cables is not supported. 100GE and 40GE copper cables can only be used on stack ports and M-LAG peer-link ports. 100G 3/5 m copper cables support only RS FEC. After the non-RS FEC mode is configured, the port enters the error-down state.
|
Service port supporting the stack function |
25GE and 100GE optical ports
|
RTC |
Supported
|
Redundant power supply |
1+1 backup
|
Redundant fans |
Supports 3+1 backup. Fan modules work in hot backup mode. If a fan module fails, the system can still work properly for a short period of time. However, you are advised to replace the faulty fan module immediately.
|
Number of power modules |
2
|
Power supply surge protection |
AC: 6 kV in common mode and 6 kV in differential mode
DC: 4 kV in common mode and 2 kV in differential mode
HVDC: 4 kV in common mode and 2 kV in differential mode
|
Types of fans |
Pluggable
|
Number of fans |
4
|
Airflow direction |
Front-to-rear or rear-to-front, depending on the selected fan modules and power modules
|
Storage temperature |
-40ºC to +70ºC (-40°F to +158°F)
|
Long-term operating temperature |
0°C to 40°C (32°F to 104°F) at an altitude of 0–1800 m (0–5906 ft.)
Note: When the altitude is 1800–5000 m (5096–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
|
Long-term operating relative humidity [RH] |
5% RH to 95% RH, non-condensing
|
Storage relative humidity [RH] |
5% to 95% RH, non-condensing
|
Storage altitude |
≤ 5000 m (16404 ft.)
|
Long-term operating altitude |
≤ 5000 m (16404 ft.)
|
MTBF [year] |
47.81 years
|
MTTR [h] |
1.95 hours
|
Noise at normal temperature (27°C, sound pressure) |
- Front-to-back airflow: < 58 dB(A)
- Back-to-front airflow: < 57 dB(A)
|
Noise at high temperature (40°C, sound pressure) |
- Front-to-back airflow: < 75 dB(A)
- Back-to-front airflow: < 74 dB(A)
|
Availability |
0.9999962836
|